OPERATION


                              Ensure the output is off before connecting any sense
                    WARNING   cables.

                              Use sense cables with a voltage rating exceeding the
                              isolation voltage of the power supply.
                              Never connect sensing cables when the output is on.
                              Electric shock or damage to the power supply could
                              result.

                              Always connect the + sense lead to the + terminal of
                              the load and the - sense lead to the - terminal of the
                              load. If a sense lead opens during operation the
                              output may momentarily overshoot. The two center
                              sense terminals are not used.
               Single Load    1.  Connect the +S terminal to the positive
                                 potential of the load. Connect the -S terminal to
                                 the negative potential of the load.

                                 PHU                    Load
                                Output                  Input

                                Output                  Input
                                    +S

                                    -S

                              2.  Operate the instrument as normal.
                                 See the Basic Operation chapter for
                                 details.
               Parallel PHU   1.  Connect the +S terminals to the positive
               Units             potential of the load. Connect the -S terminals
                                 to the negative potential of the load.